Liquid Flowmeter Calibrations by TrigasFI Calibration Laboratory

Calibration of Flowmeters

for Liquids

Liquid Flowmeter Calibrations:

TrigasFI has performed more than 100,000 gas and liquid flowmeter calibrations over the past 30 years. We are one of few laboratories able to calibrate with actual viscosities and real fluids. So we are ensuring high performance calibrations which are representative of actual operating conditions. Thanks to our experience, you can be sure that your flow meter will be optimally calibrated and adjusted. A properly calibrated device can save the cost of investing in new hardware.

Certified Quality

Liquid flowmeter calibrations – TrigasFI is DAkkS ISO 17025 accredited and can provide DAkkS certification for practically all Gas and Liquid flowmeter calibrations performed in our lab.

Service Center for TrigasDM Flowmeters

Our technicians are factory trained to perform Calibrations of TrigasDM Flowmeters, Electronics programming and scaling as well as most mechanical and electrical repairs. Fast turnaround and compliance to factory specifications is guaranteed.

TrigasDM Calibration Center

What does Trigas do differently?

Our employee list includes experts with previous experience with well known flowmeter manufacturers.
Our calibration specialists receive periodic training as part of cooperation programs we have in place with many flowmeter manufacturers.
Combining our expertise with the use of primary and secondary standards of different operating principles, we offer the best calibration precision among DAkkS accredited calibration laboratories.

We are impartial! TrigasFI is not associated with any flowmeter manufacturer. Being an Independent DAkkS laboratory ensures unbiased, reliable calibration results.

The target turnaround time for calibrations is five work days. Depending on workload, we are sometimes challenged to maintain adherence to this target, but since we know how important it is to avoid process interruptions, for emergencies we also offer a 24-hour service, and when the need is dire, even calibrate-while-you-wait service.

We will gladly organize pick up and delivery of your sensitive equipment. Depending upon location this is done by means of our own driving service or by our transport partners. 

Ranges and Specifications for Standard Liquid Flowmeter Calibrations:

Piston/Displacer Primary Standards

Oils and Water:

  • 0.00005 l/min (0.05 ml/min) to 1500 l/min
  • 0.00004 kg/min (0.04 gr/min) to 1500 kg/min
  • Accuracy: +/- 0.03% (0.04% with DAkkS certificate)
  • Viscosity range: 0.5-2000 mm²/s

 

Mass Flow Loop, Water only:

  • up to 5000 l/min – 5000 kg/min
  • Accuracy: +/- 0.05% (0.09% with DAkkS certificate)

TrigasFI Pick Up Service

We will gladly organize pick up and delivery of your sensitive equipment. Depending upon location this is done by means of our own driving service or by our transport partners – please contact us.

Send us devices for Liquid Flowmeter Calibrations

If you send us devices for calibration, we ask you kindly to enclose the following documents:

Decontamination declaration

Calibration specification

Service Terms and Conditions

Save valuable time and additional questions for a easy processing and fast turnaround time!

Some of the flowmeters we

calibrate, adjust and repair:

Turbines:

TrigasDM
FTI Flow Technology
Natec Sensors
Cox
Badger
KEM-Küppers
Sika
Hoffer
Sponsler

Gear PD Flowmeters:

VSE
Kracht
KEM-Küppers

Helical PD:

Kral
KEM-Küppers
GHM

Coriolis:

Endress+Hauser
Krohne
Bronkhorst
ABB
Siemens

Magnetic Inductive Flowmeters:

Endress+Hauser
Krohne
Siemens

Variable Area:

Krohne
Vögtlin
Rotameter / Yokogawa

Ultrasonic:

FLEXIM
KATRONIC
Systec Controls
Krohne
Endress
Keyence
SONOTEC
ELIS